Electronic ISSN 2287-0237

VOLUME

CERAMIC ON CERAMIC BEARINGS

SEPTEMBER 2012 - VOL.4 | REVIEWS ARTICLE
  1. Willert HG, Bertam H, Buchhorn GH. Osteolysis in Alloarthroplasty of the hip: The role of ultra-high mono lecular weight polyethylene wear particles. Clin Orthop Relat Res 1990;258:95-107.
  2. Amstutz HC, Campell P, Kossovsky N, et al. Mechanism and clinical significance of wear debris induced osteolysis. Clin Orthop Relat Res 1992;276:7-18.
  3. Boutin P. Total Arthroplasty of the Hip by Fritted Aluminum Prosthesis : Experimental study and 1st Clinical Applications. Rev Chir Orthop Reparatrice Appar Mot 1972;58:229-46.
  4. Oonishi H, Clarke IC, Good V, et al. Alumina hip joints characterize by run-in wear and steady-state wear to 14 million cycles in hip-simulator model. J Biomed Mater Res A 2004;70:4.
  5. Nevelos JE, Ingham E, Doyle C, et al. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 2001;22:2191-7.
  6. Boutin P, Christel P, Dorlot JM, et al. The use of dense Alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res 1988; 22:1203-32.
  7. Catelas I, Huk O, Petit A, et al. Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: Effects of size, concentration, and composition. J Biomed Mater Res 1998;41:600-7.
  8. Christel PS. Biocompatibility of surgical-grade dense polycrystalline alumina. Clin Orthop Relate Res 1992;282:10-8.
  9. Bierbaum BE, Nairus J, Kuesis D, et al. Ceramic on Ceramic bearings in total hip replacement. Clin Orthop Relate Res 2002;405:158-63.
  10. Hamadouche M, Sedel L. Ceramics in Orthopaedics. JBJS 82B:1095-9.
  11. Hannouche D, et al. Ceramics in Total Hip Replacement. Clin Orthop Relate Res 2005;430:62-71.
  12. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial, a review. Biomaterials 1999;20:1-25.
  13. A.H. De Aza, et al.Crack growth resistance of Alumina, Zirconia and Zirconia toughened Alumina ceramics for joint prosthesis. Biomaterials 2002;23:937-45.
  14. Capello WN, D’Antonio JA, Feinberg JR, et al. Ceram icon-ceramic total hip arthroplasty: update. J Arthroplasty 2008;23:39-43.
  15. Restrepo C, Parvizi J, Kurtz SM, et al. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty 2008;23:643-9.
  16. Keurentjes JC, Kuipers RM, Wever DJ, et al. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 2008;466:1438-43. 
  17. Chevillotte C, Pibarot V, Carret JP, et al. Hip squeaking: A 10 years Follow up Study. J Arthroplasty 2012;27: 1008-13
  18. Walter WL, O’Toole GC, Walter WK, et al. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty 2007;22:496-503.
  19. Poggie RA, Turgeon TR, Coutts RD. Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg Am 2007;89:367-75.
  20. Chevillotte C, Trousdale RT, Chen Q, et al. Hip Squeaking : A Biomechanical study of Ceramic-on-Ceramic Bearing Surfaces. Clin Orthop Relat Res 2010;468:345-50.
  21. Restrepo C, Parvizi J, Kurtz SM, et al. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty 2008;23:643-9.
  22. Walter WL, Insley GM, Walter WK, et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty 2004;19:402-13.
  23. Nevelos JE, Prudhommeaux F, Hamadouche M, et al. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosen- ing. J Bone Joint Surg Br 2001;83:598.
  24. Nevelos J, Ingham E, Doyle C, et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 2000;15:793.
  25. Murali R, Bonar F, Kirsh G, et al. Osteolysis in Third Generation Alumina Ceramic-on-Ceramic Hip Bearings With Severe Impingement and Titanium Metallosis. J Arthroplasty 2008;23:13-9.
  26. Dorr LD, Zhinian W, Longjohn DB, et al. Total hip arthro plasty with use of the Metasul metalon-metal articulation: Four to sevenyear results. J Bone Joint Surg Am 2000;82:789-98.
  27. Huo MH, Parvizi J, Gilbert NF. Whatʼs new in hip arthro plasty. J Bone Joint Surg Am 2006;88:2100-13.
  28. Walter WL, Lusty PJ, Watson A, et al. Stripe wear and squeaking in ceramic total hip bearings. Semin Arthroplasty 2006;17:190-5.
  29. Clarke IC, Manley MT. How do alternative bearing surfaces influence wear behavior? J Am Acad Orthop Surg 2008;16:S86-S93.
  30. Nevelos J, Ingham E, Doyle C, et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 2000;15:793-5.
  31. Walter WL, Insley GM, Walter WK, et al. Edge Loading in Third Generation Alumina Ceramic-on-Ceramic Bearings. J Arthroplasty 2004;19:402-13.
  32. Fisher J, Stewart T, Tipper J, et al. Functional biological activity and osteolytic potential of wear debris generated in artificial hip joints. Presented at: IMechE 2000, June 13-15; London.
  33. Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res 2000;379:22-8.
  34. Rack R, Pfaff HG. A new ceramic material for orthopae dics. Procs 5th International CeramTec Symposium, February 2000.
  35. Inzerillo CV, Garino JP. Alternative bearing surfaces in total hip arthroplasty. J Southern Orthop Assoc 2003;12: 106-11.
  36. Mehmood S, Riyaz JH, Pandit H. Review of ceramic-on ceramic total hip arthroplasty. J Surg Ortho Adv 2008;17:45-50.
  37. Tateiwa T, Clarke IC, Williams PA, et al.Ceramic total hip arthroplasty in the United States: safety and risk issues revisited. Am J Orthop 2008;37:E26-31.
  38. Pandorf T. How important it is to use clean taper fixations? Procs 13th International BIOLOX Symposium: Bioceramics and Alternative Bearings in Joint Arthroplasty, Edinburgh, 2009.
  39. Lombardi AV Jr, Berend KR, Seng BE, et al. Delta ceramic -on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis. Clin Orthop Relat Res 2010;468:367-74. 
  40. Hamilton WG, McAuley JP, Dennis DA, et al. THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2010;468:358-66.
  41. Min BW, Song KS, Kang CH, et al. Delayed fracture of a ceramic insert with modern ceramic total hip replace ment. J Arthroplasty 2007;22:136-9 .
  42. Sariali E, Stewart T, Mamoudy P, et al. Undetected fracture of an alumina ceramic on ceramic hip prosthesis. J Arthroplasty 2010;25:658.e1-5.
  43. Hannouche D, Nich C, Bizot P, et al. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res 2003;417:19-26.
  44. Poggie RA, Turgeon TR, Coutts RD. Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg 2007;89:367-75.
  45. Ha YC, Kim SY, Kim HJ, et al. Ceramic liner fracture after cementless alumina-onalumina total hip arthroplasty. Clin Orthop Relat Res 2007;458:106-11
  46. Park YS, Hwang SK, Choy WS, et al. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am 2006;88:780-7
  47. Toni A, Traina F, Stea S, et al. Early diagnosis of ceramic liner fracture. guidelines based on a twelveyear clinical experience. J Bone Joint Surg Am 2006;88:55-63.
  48. Hasegawa M, Sudo A, Hirata H, et al. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty 2003;18:658-61.
  49. Elkins JM, Pedersen DR, Callaghan JJ, et al. Fracture Propagation Propensity of Ceramic Liners During Impingement-Subluxation. J Arthroplasty 2012;18:520-6.