Electronic ISSN 2287-0237

VOLUME

PEDIATRIC RADIATION DOSE FROM 64 SLICES-MDCT IN ABDOMEN AFTER USING THE NEW PEDIATRIC CT SCANNING PROTOCOL AT PHRAMONGKUTKLAO HOSPITAL

SEPTEMBER 2020 - VOL.16 | ORIGINAL ARTICLE
OBJECTIVES:

To study the radiation dose in pediatric patients after using a new pediatric computed tomography (CT) scanning protocol at Phramongkutklao Hospital as compared with the historical data and with reference level recommended by International Commission on Radiological Protection (ICRP).

MATERIALS AND METHODS: 

This study was a prospective and descriptive study. The study target population were all consecutive patients aged

RESULTS:

Total of 29 children were included in the analysis, 13 were male and 16were female. The third quartile of the dose-length product (DLP) (75thpercentile) was125.0, 228.0, 305.6 and 381.0 mGy.cm for the patients < 1, 1 to < 5, 5 to < 10 and 10to 

CONCLUSION: 

The radiation dose that our pediatric patients received from undergoing CT scan of abdomen was acceptable after using the new protocol. Data collection in future studies including a higher number of patients and longer follow-up time may be helpful.

Keywords:

pediatric radiation dose, multidetector-computed tomography, MDCT, diagnostic reference level, DRL

Received: February 2, 2020

Revision received: April 7, 2020

Accepted after revision: September 9, 2020

BKK Med J 2020;16(2): 200-203.

DOI: 10.31524/bkkmedj.2020.21.014

SEARCH VOLUME & NUMBER
GO