Electronic ISSN 2287-0237

VOLUME

REVIEW OF CENTRAL VENOUS CATHETER-RELATED INFECTIONS AND UV-C AS A POTENTIAL SOLUTION

FEBRUARY 2017 - VOL.13 | REVIEWS ARTICLE
  1. Smith RN, Nolan JP. Central venous catheters. BMJ 2013;347:f6570. 
  2. Raad I, et al. Nosocomial infections related to use of intravascular devices inserted for long-term vascular access. In: Mayhall C, ed. Hospital Epidemiology and Infection Control. Philadelphia, Pa: Lippincott Williams & Wilkins; 1999:165-172. 
  3. Shah H, Bosch W, Thompson KM, et al. Intravascular Catheter-Related Bloodstream Infection. Neurohospitalist 2013;3(3):144-151.
  4. Drewett SR. Central venous catheter removal: procedures and rationale. Br J Nurs 2000 (22):2304-15 
  5. Sasadeusz KJ, Trerotola SO, Shah H, et al. Tunneled Jugular Small-Bore Central Catheters as an Alternative to Peripherally Inserted Central Catheters for Intermediate-term Venous Access in Patients with Hemodialysis and Chronic Renal Insufficiency. Radiology 1999; 213(1): 303-6. 
  6. Frasca, D, Dahyot-Fizelier, C, Mimoz, O. Prevention of central venous catheter-related infection in the intensive care unit. Critical Care 2010;14:212. 
  7. Yevslin AS, Arif A, Loay S. Interventional Nephrology:Principles and Practice. 2014. 
  8. Mermel LA. What Is The Predominant Source of Intravascular Catheter Infections? Clin Infect Dis 2011;52(2):211–2. 
  9. Mathur P. Hand hygiene: Back to the basics of infection control. Indian J Med Res 2011;134(5):611-20. 
  10. Dancer S. Controlling Hospital-Acquired Infection: Focus on the Role of the Environment and New Technologies for Decontamination. Clin Microbiol Rev 2014;27(4):665-90. 
  11. Chopra V, Olmsted R, Safdar N, et al. Prevention of Central Line-Associated Bloodstream Infections: Brief Update Review. In: Krein S, editor. Making Health Care Safer II: An Updated Critical Analysis of the Evidence for Patient Safety Practices. Rockville; 2013. 
  12. Shapey I, Foster M, Whitehouse T, et al. Central venous catheter-related bloodstream infections: improving postinsertion catheter care. J Hosp Infect 2009;71(2):117-22. 
  13. Pronovost D, Needham D, Berenholtz S, et al. An intervention to decrease catheter-related bloodstream infections in the ICU.N Engl J Med 2006; 355(26): 2725-32. 
  14. Gahlot R, Nigam C, Kumar V, et al. Catheter-related bloodstream infections. Int J Crit Illn Inj Sci 2014; 4(2):162-7. 
  15. Mah TF, O’Toole GA. Mechanisms of biofilm resistance to antimicrobial agents. Trends Microbiol 2001;9(1):34-9. 
  16. Wilkins KM, Hanlon GW, Martin GP, et al. The migration of bacteria through gels in the presence of IUCD monofilament tails. Contraception1989;39(2):205-16. 
  17. Wolfe AJ, Berg HC. Migration of bacteria in semisolid agar. Proc Natl Acad Sci U S A 1989;86(18):6973-7. 
  18. Harkes G, Dankert J, Feijen J. Bacterial migration along solid surfaces. Appl Environ Microbiol1992;58(5):1500-5 
  19. Garrett, TR, et al. Bacterial adhesion and biofilms on surfaces. Progress in Natural Science 2008;18(9):1049-56. 
  20. Sudarsan, R, Ghosh S, Stockie JM, et al. Simulating biofilm deformation and detachment with the immersed boundary method. Communications in Computational Physics 2016;19(3):682-732. 
  21. Shunmugaperumal, T. Biofilm Eradication and Prevention: A Pharmaceutical Approach to Medical Device Infections; 2010:78. 
  22. Mascari L, Ymele-Leki P, Eggleton C, et al. Fluid Shear Contribution to Bacteria Cell Detachment Initiated by a Monoclonal Antibody. Wiley Periodicals. 2003.
  23. Lecuyer S, Rusconi R, Shen Y, et al. Shear stress increases the residence time of adhesion of Pseudomonas eruginosa.Biophys J 2011;100(2):341-50.
  24. Stewart PS. Biophysics of biofilm infection. Pathog Dis 2014;70(3):212-8
  25. Doran AK, Ivy DD, Barst RJ, et al. Guidelines for the prevention of central venous catheter-related blood stream infections with prostanoid therapy for pulmonary arterial hypertension. Int J Clin Pract Suppl 2008;62:5-9.
  26. Drewett SR. Central venous catheter removal: procedures and rationale. Br J Nurs 2000;9(22):2304-15. 
  27. Kim DK, Gottesman MH, Forero A, et al. The CVC removal distress syndrome: an unappreciated complication of central venous catheter removal. Am Surg 1998;64(4):344-7. 
  28. Chaftari A-M, Zakhem AE, Jamal MA, et al. The use of minocycline-rifampin coated central venous catheters for exchange of catheters in the setting of staphylococcus aureus central line associated bloodstream infections. BMC Infect Dis 2014;14:518.
  29. Doran AK, Ivy DD, Barst RJ, et al. Guidelines for the prevention of central venous catheter-related blood stream infections with prostanoid therapy for pulmonary arterial hypertension. Int J Clin Pract Suppl 2008;62:5-9.
  30. Jacob J. Pathophysiology of Sepsis. Am J Heal Pharm 2002;136:1-51.
  31. Klingenberg C, Aarag E, Rønnestad A, et al. Coagulasenegative staphylococci sepsis in neonates. Association between antibiotic resistance, biofilm formation, and the host inflammatory response. Pediatr Infect Dis J 2005; 24(9):817-822.
  32. Furuya YE, Dick A, Perencevich EN, et al. Central line bundle implementation in US intensive care units and impact on bloodstream infections. PLoS One 2011;6(1):e15452.
  33. Pradeep Kumar SS, Easwer HV, Maya Nandkumar A.Multiple drug resistant bacterial biofilms on implanted catheters - a reservoir of infection. J Assoc Physicians India 2013;61(10):702-7.
  34. Menyhay S, Maki D. Disinfection of needleless catheter connectors and access ports with alcohol may not prevent microbial entry: the promise of a novel antiseptic-barrier cap. Infect Control Hosp Epidemiol 2006;27(1):23-7.
  35. Rabindranath KS, Bansal T, Adams J, et al. Systematic review of antimicrobials for the prevention of haemodialysis catheterrelated infections. Nephrol Dial Transplant 2009;24(12):3763-74.
  36. Theaker, C, Juste R, Lucas N, et al. Comparison of bacterial colonization rates of antiseptic impregnated and pure polymer central venous catheters in the critically ill. J Hosp Infect 2002;52(4);310-2.
  37. Sánchez-Prado L, Llompart M, Lores M, et al. Further research on the photo-SPME of triclosan. Anal Bioanal Chem 2006;384(7-8):1548-57.
  38. Hoiby N, Bjarnsholt, T, Givskov M, et al. Antibiotic resistance of bacterial biofilms. Int J Antimicrob Agents 2010;35:322-32.
  39. Crnich CL, Maki DG. Are Antimicrobial-impregnated catheters effective? Don’t throw out the baby with the bathwater. Clin Infect Dis 2004;38(9):1287-92.
  40. Skovgaard S, Nielsen L, Larsen M, et al. Staphylococcus epidermidis isolated in 1965 are more susceptible to triclosan than current isolates. PLoS One 2013;8(4):e62197.
  41. Brunelli SM, Njord L, Hunt AE, et al. Use of the Tego needlefree connector is associated with reduced incidence of catheter-related bloodstream infections in hemodialysis patients. Int J Nephrol Renovasc Dis 2014;7:131-9.
  42. Cookson ST, Ihrig M, O’Mara EM. Increased bloodstream infection rates in surgical patients associated with recommended use and care following implementation of a needleless device. Infect Control Hosp Epidemiol 1998;19:23-7.
  43. Soi V, Moore CL, Kumbar L, et al. Prevention of catheterrelated bloodstream infections in patients on hemodialysis: challenges and management strategies. Int J Nephrol Renovasc Dis 2016; 9:95-103.
  44. Luther MK, Bilida S, Mermel LA, et al. Ethanol and Isopropyl Alcohol Exposure Increases Biofilm Production in Staphylococcus aureus and Staphylococcus epidermidis. Infect Dis Ther 2015;4(2):219-26.
  45. WrightMC, Tropp J, Schora DM, et al. Continuous passive disinfection of catheter hubs prevents contamination and bloodstream infection. Am J Infect Control 2013;41(1):33-8.
  46. Landry DL, Braden GL, Gobeille SL, et al. Emergence of gentamicin-resistant bacteremia in hemodialysis patients receiving gentamicin lock catheter prophylaxis. Clin J Am Soc Nephrol 2010;5(10):1799-804.
  47. Solomon LR, Cheesbrough JS, Bhargava R, et al. Observational study of need for thrombolytic therapy and incidence of acteremia using taurolidine-citrate-heparin, taurolidinecitrate and heparin catheter locks in patients treated with hemodialysis. Semin Dial 25(2):233-8.
  48. Justo JA, Bookstaver PB. Antibiotic lock therapy: review of technique and logistical challenges. Infect Drug Resist 2014;7:343-63.
  49. Downes A, Blunt TP. On the Influence of Light upon Protoplasm. Proceedings of the Royal Society of London. 1878;28(190-195):199-212.
  50. Moller K, Kongshoj B, Philipsen P, et al. How Finsen’s light cured lupus vulgaris. Photodermatology, Photoimmunology and Photomedicine 2005;21(3):118-124.
  51. Wallner-Pendelton E, Sumner S, Froning G, et al. The use of ultraviolet radiation to reduce salmonella and psychrotrophic bacterial contamination on poultry carcasses. Poult Sci 1994;73(8):1327-53.
  52. Rowan NJ, MacGregor SJ, Anderson JG, et al. Pulsed-light inactivation of food-related microorganisms. Appl Environ Microbiol 1999;65(3):1312-5.
  53. Steven C, William B. Ultraviolet Light Disinfection in the Use of Individual Water Purification Devices. 2006 (Accessed November 1, 2016 at file:///C:/Users/Pasuta/Documents/V%2013/final%20AW/ADA453967.pdf).
  54. Song K, Mohseni M, Taghipour F. Application of ultraviolet light-emitting diodes (UV-LEDs) for water disinfection: A review. Water Res 2016;94:341-9.
  55. Reed NG. The history of ultraviolet germicidal irradiation for air disinfection. Public Health Rep 2010;125(1):15-27.
  56. Turnbull P, Reyes A, Chute M, et al. Effectiveness of UV Exposure of Items Contaminated with Anthrax Spores in a Class 2 Biosafety Cabinet and a Biosafety Level 3 Laboratory Pass-Box. Applied Biosafety 2008;13(3):164-8.
  57. Kramer A, Schwebke I, Kampf G. How long do nosocomial pathogens persist on inanimate surfaces? A Systematic Review. BMC Infect Dis. 2006;6:130.
  58. Dai T et al. Ultraviolet C irradiation: an alternative antimicrobial approach to localized infections? Expert Rev Anti Infect Ther 2012;10(2):185-95.
  59. Russell AD. Ultraviolet radiation. In: Russell AD, Hugo WB,Ayliffe GAJ, eds. Principles and practices of disinfection, preservation and sterilization. Oxford: Blackwell Science,1999:688-702.
  60. Unluturk S, Atilgan MR, Baysal AH, et al. Use of UV-C radiation as a non-thermal process for liquid egg products (LEP). J Food Eng 2008;85:561-8
  61. U.S. Food and Drug Administration. Kinetics of Microbial Inactivation for Alternative Food Processing Technologies -- Ultraviolet Light. (Accessed November 1, 2016 at http:// www.fda.gov/Food/FoodScienceResearch/SafePracticesforFoodProcesses/ucm103137.htm).
  62. Anderson DJ, Gergen MF, Smathers E, et al. Decontamination of Targeted Pathogens from Patient Rooms Using an Automated Ultraviolet-C-Emitting Device. Infect Control Hosp Epidemiol 2013;34(5):466-71.
  63. Owens MU, Deal DR, Michael O, et al. High-Dose Ultraviolet C Light Inactivates Spores of Bacillus Atrophaeus and Bacillus Anthracis Sterne on Nonreflective Surface. Applied Biosafety 2005;10(4):240-7.
  64. Boyce JM. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals. Antimicrob Resist Infect Control 2016;5:10.
  65. Lin R, Prologo J. Inactivation of Bacteria on Explanted Dialysis Catheter Lumens with Fiber Optically Delivered Ultraviolet Light. J Vasc Interv Radiol 2015;26(12):1895-9.
  66. Nerandzic MM, Cadnum JL, Eckart KE, et al. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens. BMC Infect Dis 2012;12:120.
  67. Nerandzic M, Cadnum J, Pultz M, et al. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010;10(1):197.
  68. Haas J, Menz J, Dusza S, et al. Implementation and impact of ultraviolet environmental disinfection in an acute care setting. Am J Infect Control 2014;42(6):586-90.
  69. Rao BK, Kumar P, Rao S, et al. Bactericidal effect of ultraviolet C (UVC), direct and filtered through transparent plastic, on gram-positive cocci: an in vitro study. Ostomy Wound Manage 2011;57(7):46-52.
  70. Taylor G, Bannister G, Leeming J. Wound disinfection with ultraviolet radiation. J Hosp Infect 1995;30(2):85-93.
  71. Dai T, Murray C, Vrahas M, et al. Ultraviolet C light for Acinetobacter baumannii wound infections in mice. J Trauma Acute Care Surg 2012;73(3):661-7.
  72. Nerandzic MM, Fisher CW, et al. Sorting through the wealth of options: comparative evaluation of two ultraviolet disinfection systems. PLoS One 2014Sep23;9(9).
  73. Umezawa K, Asai S, Inokuchi S, et al. A Comparative study of the bactericidal activity and daily disinfection housekeeping surfaces by a new portable pulsed UV radiation device. Curr Microbiol 2012;64(6):581-7.
  74. Menyhay SZ, Maki DG. Disinfection of needleless catheter connectors and access ports with alcohol may not prevent microbial entry: the promise of a novel antiseptic barrier cap. Infect Control Hosp Epidemiol 2006;27(1):23-7.
  75. Tran T, Racz L, Grimaila M, et al. Comparison of continuous versus pulsed ultraviolet light emitting diode use for the inactivation of Bacillus globigii spores. Water Sci Technol 2014;70(9):1473-80.
  76. Würtele M, Kolbe T, Lipsz M, et al. Application of GaN-based ultraviolet-C light emitting diodes – UV LEDs – for water disinfection. Water Res 2011;45(3):1481-9.
  77. Dujowich M, Case J, Ellison G, et al. Evaluation of Low-Dose Ultraviolet Light C for Reduction of Select ESKAPE Pathogens in a Canine Skin and Muscle Model. Photomed Laser Surg 2016;34(8):363-70.
  78. Dean S, Petty A, Swift S, et al. Efficacy and safety assessment of a novel ultraviolet C device for treating corneal bacterial infections. Clin Exp Ophthalmol 2011;39(2):156-63.
  79. Messina G, Fattorini M, Nante N, et al. Time Effectiveness of Ultraviolet C Light (UVC) Emitted by Light Emitting Diodes (LEDs) in Reducing Stethoscope Contamination. IJERPH 2016;13(10):940.
  80. Tønnesen H. The photostability of drugs and drug formulations. 2nd ed. Boca Raton: Taylor & Francis; 2004.
  81. Boettner E, Wolter J. Transmission in the ocular media. Investigative Ophthalmology & Visual Science 1962;1:776-83.
  82. Verhaar R, Dekkers D, De Cuyper I, Ginsberg M, de Korte D, Verhoeven A. UV-C irradiation disrupts platelet surface disulfide bonds and activates the platelet integrin αIIbβ3.Blood 2008;112(13):4935-9.
  83. Turker H. Haematological effects of Ultraviolet-C Radiation extract on Swiss Albino Mice. Int J Toxicology Applied Pharm 2014;4(1):17-22.
  84. Altinaş A, Bilgili A, Eşsiz D, et al. Effects of artificial ultraviolet C radiation on several blood and urine parameters related to renal and hepatic functions in albino mice. BulletinVeterinary Institute in Pulawy 2007;51:303-8.
  85. Bak J, Jørgensen T, Helfmann J, et al. Potential in vivo UVC disinfection of catheter lumens: estimation of the doses received by the blood flow outside the Catheter tip hole. Photochem Photobiol 2011;87(2):350-6.
  86. Mohr H, Steil L, Gravemann U, et al. Blood component: A novel approach to pathogen reduction in platelet concentrates using short-wave ultraviolet light. Transfusion 2009;49(12):2612-24.
  87. Kogelschatz U. Advanced Ozone Generation. Process Technologies for Water Treatment. 1988;87-118.
  88. Eliasson B, Kogelschatz U. Ozone Generation with Narrow–Band UV Radiation. Ozone: Science & Engineering 1991;13(3):365-73.
  89. O’Donnell C. Ozone in food processing. Hoboken: John Wiley & Sons; 2012.
  90. Summerfelt S. Ozonation and UV irradiation—an introduction and examples of current applications. Aquacultural Engineering 2003;28(1-2):21-36.
  91. Zhang A, Elmets C, Elston D. Drug-Induced Photosensitivity [Internet]. : Background, Pathophysiology, Epidemiology. (Accessed November 1, 2016, at http://emedicine.medscape.com/article/1049648-overview).
  92. Lugovic L, Situm M, Ozanic-Bulie S, Sjerobabski-Masnee I.Phototoxic and Photoallergic Skin Reaction. Coll Anthropol 2007;31:63-7.
  93. Ceppatelli M, Fanetti S, Citroni M, et al. Photoinduced Reactivity of Liquid Ethanol at High Pressure. J Phys Chem B 2010;114(47):15437-44.
  94. Ha J, Ha S. Synergistic effects of ethanol and UV radiation to reduce levels of selected foodborne pathogenic bacteria. JFood Prot 2010;73(3):556-61.
  95. Revelle L, Doub W, Wilson R, Rutter A. Synthesis of C h l o r h e x i d i n e D i g l u c o n a t e I m p u r i t i e s . P h a r m Res1994;10(12):1777-84.
  96. Sheldon JL, Kokjohn TA, Martin EL. The effects of salt concentration and growth phase on MRSA solar and germicidal ultraviolet radiation resistance. Ostomy Wound Manage 2005;51(1):36-8, 42-4, 46.
  97. Khan K, Farooq R, Iqbal M. Chemical effects of UV radiation on aqueous solutions of heparin-Ca salt. Polymer Photochemistry 1985;6(6):465-74.
  98. Ehrlich J, Stivala S. Chemistry and Pharmacology of Heparin.J Pharm Sci 1973;62(4):517-44.
  99. Reddick A, Ronald J, Morrison W. Intravenous fluid resuscitation: was Poiseuille right? Emerg Med J2011;28:201e202.
SEARCH VOLUME & NUMBER
GO
RECENT VOLUME & NUMBER